3/20/2021 0 Comments S7 200 Pc Access Manual Programs
First time I used the S7.Net library, but I was only able to get it working with PLCSIM, not with real PLC.
![]() You can place a breakpoint in Visual Studio and debug the messages sent and received from the TCP socket without having to leave Visual Studio and without having to use network sniffers or other external software. Now ReadMultiVars and WriteMultiVars dont require pointers and memory management. In case of Sharp7 this is the library itself, as there are no binaries to be included. S7300-S7400 supports every function, while newer plcs can only read and write data. It will show how to connectdisconnect, read and write block of DB and multiple variables. This unit has to be configured properly (see page 12 of the user manual). Then pass it to the Read function to populate it with the data from the cpu, then convert all the data from S7 format to C format. We have to create a buffer, populate it with the data (converted in S7 format) that we need to write, and then call the Write function. Also, since our buffer starts from 4.0, we must set the start index to 4. One has to be really careful with indexing, so what I usually do when creating the buffer is to use the real offset of the variable and to subtract the start index. S7 200 Pc Access Programs Code To WriteSo here is the code to write DB1.DBD4, DB1.DBD8 and DB1.DBD12. Example: lets suppose, we want to read with a single request the values from DB1 and DB3. The S7MultiVar variables have a method Read, which populates all the buffers with the data from the plc. We have to create a buffer for every variable we want to write, then we populate the buffer with the converted values that we want to write, and then we call the Write method. In this case we will write the DB1 and DB3 values from offset 2 to offset 8. Also software written in C scales well if you have a lot of programmers working on it. And if you need charts, gauges and other controls, there is plenty of them. In Asia learning curve doesnt matter. S7 200 Pc Access Programs License Is EqualWinCC license is equal to 5 months of fresh automation engineer salary. It means that you are probably reading more than you can read. Its better to you as many connections as many threads you have. Now I have a new instance for each thread (one client to read, another to write) and it is working fine. Thank you.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |